Heat pump performance is often quoted as a single nominal COP, yet in practice the coefficient of performance drops as the outdoor temperature falls and as the required flow temperature rises. As an installer of heat pumps and photovoltaic systems, we find it more useful to model this dependency than to rely on the rated value. A simple approach in Maple is to start from the Carnot limit, the condensing temperature divided by the difference between condensing and evaporating temperatures (both in kelvin), and then apply an efficiency factor fitted to manufacturer data with Statistics:-Fit or CurveFitting:-LeastSquares. Combining the fitted curve with hourly outdoor temperatures over a heating season gives a seasonal estimate that is far closer to what customers actually experience. A frequent mistake is to keep the flow temperature fixed: a lower flow temperature, as with underfloor heating or a weather compensation curve, noticeably improves the COP, so the emitter choice belongs in the model. We would welcome other approaches from members who have coupled such a model with photovoltaic production profiles to estimate self-consumption.